You would need to do some of the troubleshooting mentioned in the guide if you want any certainty. Note how the wires areattached so you can replace them correctly when the plug is reattached. TEST3A - CHECK AMPHENOLPLUG - Reconnect the power cord to the Power Supply. I took apart the unit and found the drive gear and a guide wheel were busted up with bearings falling out. Posted: 4/25/2022, Nautilus CC Plus Out of Water Test
We discuss the danger and what you can do about it! The motor is receiving power but is not turning; if the shafts are frozen, the motor is dead and should be replaced. Thanks. Drop enough of the power cord into the pool so that the cleaner can reach the farthest corner. Posted: 4/16/2021, Joel
The only replacement parts I could find for the. Power supply powers up but I am not getting any activity at the cleaner itself. I have followed the troubleshooting techniques in your video, but would like to get something clarified. So come on down to Wild West Pool Supplies, where the water is always clean, cool and fun to dive right into!
When running this test, the POWER MUST BE OFF, and the meter should be set at the continuity setting as shown. Turn the power supply ON. S200 99996202-US, S300 99996221-US, S300i 99996225-US, Active 20 99996023-US, Active 30 99996231-US, Active 30i 99996235-US, Prowler 920 99996201-US, Prowler 930 99996214-US, Discovery 99996201-DIS, Saturn 99996114-SAT, Cayman 99996135-SPL, Quantum 99996203-SPL, Premium 99996211-PIO.
Exclusively at Wild West Pool Supplies, we can now proudly offer our best price yet on the Maytronics Power Supply9995670-US-ASSY. The power supply is putting out 21.2 VDc (measured right at power supply). The red wire is the ground. DIAL METER FORDCTEST -TheDC side of the meter hasfour test ranges. Or, it might starve an active unit from the necessary power for standard operation, leading to unexpected issues. Same Day Shipping. Our customers can rest assured: the Maytronics Dolphin 9995670-US-ASSY Power Supply comes with a one (1) year warranty directly from Maytronics. Do you have any questions or concerns about replacing your Nautilus Plus power supply? Once powered back on, the same cycling happens, lights stay on for 2.5 mins or so, power 29v on DC out, then fades to 00 again. If the meter shows 0V DC go toTest 6A. Also, does one motor /impeller keeping working while the other turning off soon indicate a motor problem or maybe a yet to be found mechanical problem? If continuity fails, you will have to replace theAmphenolPlug. Model 9995678 power supply, Power light comes on steady, no mode selection lights come on any longer.
It has provided me and others a lot of good information. Maytronics rigorously tests their products, and backs them with a warranty guarantee against short-term malfunctions. Go toTest4. If the meter shows 29V, you are getting power to the motor. instructions for how to enable JavaScript in your web browser, Click Here to View Replacement Dolphin Pool Cleaner Parts, Motor Unit D.basic 3 Hour Ac New (99953003-assy). I tested the cable for continuity and its good. For the premium price, thats disappointing. For the most part, customers really appreciate how easy this machine is to set up and operate, despite the lackluster owners manual. It sounds like you have a power supply failure. Several people appreciated that all the filters are included without having to buy them separately. We will never hesitate to pass along any tips or advice. The impeller (in perfect condition-new) will not start, however, the wheels are working fine. Fits several models of Dolphin pool robots. Any thoughts? I have a more recent unit, so I seem to see a fuse solded to the board. But we list a few different ways to troubleshoot the motor in the guide correctly. But that is a guess. Our pool maintenance expert, Luke Reed, earned his BS in Civil Engineering from Georgia Tech in 1998. Youll attach the power cord to the power supply and turn it clockwise to lock. Then place the meter probes on the tworaw wires. This part, at this price? I would not recommend this product to anyone, yet to find any practical use for a scheduling option on the robots. Back to same problem. The DC out plug has continuity. Move the probes to the ends of the other wire and test it for continuity, If you don't have continuity on both wires, the cord is bad and needs to be replaced. Is power pack 995670 compatible?? Its a 09/2005 model yellow. No matter the size, shape, or type of pool, nothing cleans like a Dolphin. It will not power back on, unless the power cord is disconnected from the supply for 15 sec or so. Copyright 2019-2020 Marina Pool Spa & Patio. Some local service centers werent able to do the repairs either because they werent capable or because customers didnt purchase the robot directly from them. After 2.5 minutes, the power light goes out, and the DC voltage drops to .01, then fades to 00. If you are testing for voltages above 200V and up to 600V, you would set your meter to 600V. Posted: 4/5/2022, InyoPools Product Specialist Matt S.
This top-tier Maytronics Dolphin Power Supply9995670-US-ASSYis at 15% off only as long as our current stock holds out, though, so don't wait! Either CS was unresponsive or requested they ship the whole unit back.
Dolphin robotic pool cleaners clean any type or shape of pool efficiently and thoroughly. Posted: 9/7/2021, InyoPools Product Specialist Matt S.
At this point, if theCleaner is not still under warranty, it is usually cheaper to buy a new cleaner than sending the cleaner out for a motor replacement. Depending on the age of the cleaner, it may be best to get a whole new unit because motors are expensive. Posted: 5/29/2022, InyoPools Product Specialist Matt S.
Whether or not the track spins could have more to do with guide wheels and brushes than the motor itself. I have a maytronics DX3 pool cleaner and the power supply have 123 volts going in to the power supply and there are 63 volts coming out of the power supply. If your Power Supply is newer (without screws), it does not have a fuse and you will have to replace thePower Supply. The cartridges easily snap in and out and can be quickly hosed clean. Posted: 4/21/2021, Vinny
Easy to operate, and with easy filter emptying and cleaning, they do the work, so you dont have to. Its machine washable but can be hosed out as well.
What do you do when your MaytronicsDolphin Pool Cleaners stops running or there are no lights on the Power Supply? I have checked all of the cables everything seems fine. [emailprotected]. PLEASE NOTE: Power Cable Sold Separately. Sometimes these jobs are done by one motor or two separate motors just mounted in the same box. Your pool cleaner may be just a simple AC replacement away from being fully operational once more. Troubleshooting:
Once we sell out, we can't guarantee this amazing price. What is the part number of your power supply? If you see a reading of between 120V and 130V, your wall outlet is good and you have successfullypassed Step 1. Read our guide to the different types of swimming pools before making your decision. my power light switch will light up but the 1 2 3 cycle lights will not come on. Since we will be testing forDC voltageof 29V after the Power Supply Transformer, we willbe setting the meter at 200. Issues with tangle free swivel cord shorting out?, ussues with cleaning steps? This is where the Dolphin Premier could use some improvement. Do you want your pool cleaned every day, every other day, or every 3rd day? Posted: 3/21/2022, Dolphin premier stop moving after minutes or secs
The correct replacementfor your cable is the. 9995670, PD 5012, SN HG5012A10956
It sounds like your impeller motor has failed.
When used in conjunction with the 4 different cleaning modes, this little robot can pick up everything from leaves and sticks to sand and algae. Maytronics Dolphin Pool Cleaner Power Supply | 9995670-US-ASSY, Maytronics Product Number:9995670-US-ASSY, Replacement AC adapter for Dolphin Nautilus Plus Robotic Pool Cleaners, Compatible with standard full AC power cords. TEST 5A - TEST DOLPHINMOTOR - To test fora bad motor you will have to disconnect the Cable from the top of the motor. Not only is pool maintenance business, in our spare time it's our hobby! If the continuity check on the fuse is negative, replace the fuse. Posted: 3/18/2022, InyoPools Product Specialist Matt S.
The equipment lasts for many years, often outliving the natural life of the included AC adapter. The voltageshould be around 29 volts, like the 2-wire version. the upper limits of which are labeled 2, 20, 200, and 600. If you are testing the circuit for voltage, you need to go the length of the circuit to see where the voltage stops. Ifthe continuity checks are successful, check that you are getting a good connection at the end of the plug on the Power Cable and that all of the pins are in the Power Supply plug. Then place the two probes from the multimeterinto the wall outlet. I have a Maytronics 99996333-DX3 Dolphin Robotic Pool Cleaner. Trying to determine if i need a new motor unit, power supply. All Maytronics Parts Available. Posted: 8/11/2021, Pool Daddy
Posted: 9/8/2020, InyoPools Product Specialist Matt S.
Get your pool cleaner PSU, made by the original manufacturer, for a price that can't be beat! It is compatible with all standard full AC cords, and Maytronics offers a specially branded version with their guarantee behind it. Posted: 6/2/2022, Claybert Coury
Then place a probe on either side of the plug as shown. Don't over tighten. This is a natural process; any PSU can only handle so many power cycles over the years before it starts losing efficiency, eventually hitting a point where it doesn't charge at the rate it used to. It is machine washable and can be hosed out, but takes some time. The older style Power Supplies have screwsin the bottom plate that can be removed for access to the fuse. So it shouldnt be too hard to lift and drop into the pool. Each of these tests may be broken down into a series of subtestssuch as Test 3a, Test 3b, etc, depending on the success or failureat each stage of the test. If you have several trees around the pool, youll appreciate the bag. It comes on for a bit then the just turns off the reset button and test button wont work on the black power cable clicks off straight away. I will work through the steps you have listed here and hopefully it is a cable issue. TEST 3C - If you got 0V in the previous step, you will need to take a closer look at the AmphenolPlug.TURN THE POWER OFF. The power outlet, and supply cable test good, 120 v. When first powered on, the blue lights come on, and 29 v register on the DC out. I have the nautilus preimer. Any ideas? On the 3 power supply pins, i get differential voltages of 28.8, 26.2, and 2.6v when the robot is not connected. Customers recommended watching videos on YouTube to see how its done. Not quite sure how to interpret the voltage on the amphenol plug. However, the caddy is very useful for transporting and storage. Specifications. I don't know if it is supposed to spin freely, turning both ways. You are missing a '9' at the beginning of both of those part numbers. I took everything off the motor that would be a load and plugged it into the power supply, but get the same result. Lightweight and durable, this caddy makes storing and transporting your pool robot easy. Posted: 8/20/2021, InyoPools Product Specialist Matt S.
Multi-media filtration includes 3 filter options: bottom-load fine cartridge filters, ultra-fine cartridge filters, and a large fine filter bag. The power supply is 2 years old. I think Laura and I are having the same issue except now my power supply will not turn on at all now. Though the reusable filter bag holds a lot of debris, its not particularly easy to clean out. Can you tell me what the voltage reading should be across the red wire? Could this be a power supply issue or is something else likely?
Using a Phillips head screwdriver, unscrew the middle screw and lift off the Impeller cover. Some customers mentioned how the components are easily taken apart if something breaks so you dont have to ship the whole thing for most repairs. Make sure to test both of the two circuits through the plug. Filtration is what separates the good pool robots from the not-so-good ones. When I test my nautilus cc plus out of water, is is the track supposed to spin only one way, or spin one way, then reverse the other way? When the cleaner does run intermittently, is it herky-jerkyor does it run as usual? But it might be worth it in the long run. The cleaner doesn't remember a map of the pool. DIAL METER FOR CONTINUITY TEST -A continuity test measures for a break in an electrical line, like the Dolphin Cleaner cable. MAJOR DISCOUNT ALERT FOR POOL OWNERS: This power supply for the Nautilus Plus Robotic Pool Cleaner is the worry-free official replacement you need, and it's availablenowat an absolutely bonkers 15% off MSRP -- with FREE shipping in the Continental US, to boot!