Expedited Shipping Available - Shipping rates calculated at Checkout. The interior dimensions of a basement aren't a major factor in sizing a sump pump correctly. Located in NW Ohio and water table is fairly high.
The switch on the Zoeller M53 has about a 4 1/4" differential so by raising your pump in your basin, you will effect the level at which the pump will activate, however you will NOT effect how much water is pumped out. But I was wondering does this need more than a 15 amp outlet, due to start up amps? The pump starts smooth but when it switches off it rattles the pipes. I have a Zoeller M53 1/3 hp sump pump. That answer would be based on how much water you feel you would need to pump during a power outage. Some are more efficient than others. I have a M53-D Zoeller pump that is about 10yrs old.I was told by my home builder that it was rated to pump vertical up to 10ft.is this true?I have miss placed my owners manual and now the switch is bad so that the pump runs constant till it over heats,is that do to pumping vertical for 10yrs out of my basement for a washer?By the way it has been a great pump and will never own anything but a Zoeller for the rest of my time.Thank you. every hour for maybe 5 seconds max. ", Designed for rapid heat dissipation and extended life, Offers years of reliable, trouble-free operation, Oil-filled and hermetically sealed to prevent overheating, Assures maximum protection for extended pump life, No screen to interfere with flowing debris, Entire unit is pressure tested after assembly. I am getting a portable generator and want to include my zoeller m53-d pump to be one of the items supported by the generator. Zoeller 1050001 13 HP M53 Remote SinkDrain Pump System w Vertical Float Switch Your only option would be to either replace the pump with a different type of switch, possibly a tether or electronic switch or by rigging the switch on your M53 to stay on and then add another "piggyback" style switch. Should the switch compartment of the M53 remain above the waterline or be watertight, because when i opened to determine if i should replace the switch a lot of water came out. I plan to replace a non working Zoeller M53 in a recently purchased house with a new Zoeller M53. It is designed to handle a maximum of 15 feet of vertical lift. In that case, your best defense is a higher output. The weep hole will help to prevent any air lock within your discharge pipe between the pump and check valve. What is the model # I should buy. Is there a big difference between the M53 and M98 when it comes to noise and cycle rate? Do you still need to drill an air relief hole in your pipe if this pump has an air relief hole? The main pump will be set to activate at about 12 inches of water and the secondary pump will be set to activate at about 14-16 inches of water in the event the main pump cannot handle the amount of water coming in. The discharge on the Zoeller M53 is 1-1/2" and as such, you should resort to that same size piping to achieve optimum performance and pumping capacity. The pump runs due to the float switch being raised, but can't eject the water because of the airlock condition. The the pump works fine. How far will this pump move the water? Pump warranties vary from 1 year to 5 years depending on the pump and the manufacturer. Thank you for your interest in Sump Pumps Direct. It is at least 7 years old. A vertical float switch is a ball that floats above the water. Is the 1 inch pipe OK, or is it necessary to change to 1 1/2 inch pipes? I am thinking of buying the Zoeller M53 - 1/3 HP Cast Iron Submersible Sump Pump w/ Vertical Float Switch. Typical installations will include the discharge PVC Sch40 pipe screwed into the pump discharge port and extending approximately 2-3 feet above the sump basin cover. When it rains, my pit fills up very quickly and the pump goes every 2-3 minutes. Under normal operating conditions, it is NOT uncommon for the pump and switch housing to be completely submerged. That really depends on the pump. Thank you, I found it running with no water in the pit,unplugged it and moved the float up and down a few times and plugged it back in, and it is working okay now. I think only only one model m53 can be ordered through Sears. Is the Zoeller m53 availiable with a longer cord? This water rushing into this trench will have sand mixed in. We are based in Bolingbrook, Illinois and only operate out of this single location. If water has seeped into the switch housing, this would certainly compromise the performance and safety of the pump and I would highly recommend replacing the pump. The M53 has a cast iron switch case, motor and pump housing with an engineered thermoplastic base and an engineered, glass filled, plastic impeller with metal insert where as the M57 is all cast iron construction including the impeller. Rebekah, Zoeller basically builds 2 models, the 1/3HP model. We do carry other brands that will also be compatible with your pump and are capable of pumping more if you feel you need it. The house sits lower than both the street in front and back. The pump pumps up 1.5' then 25'to the 4" drain line. I want to say this pump is at least 30 years old. And that is to inspect your pump, float switch and sump basin every 4-6 months to insure that they are operating properly and there is no debris in your basin that could impede the pump or float switch operation. When it gets water in the pit again, the airlock condition shows up. My pit is 15" across by 24" deep. The minimum sump basin size relates to the minimum size of your sump basin or pit, that a specific pump will safely operate in. A lot of homeowners will install 2 sump pumps in their sump basin for this type of situation. Drill the hole at a 45-degree angle so the hole is pointing toward the bottom of your sump basin. No head, actually probably a foot or two lower. When using generators, you should never load them up any more that 80% of their capacity at any time, so you might consider a generator with about a 4000 watt starting watt capacity. Get helpful tips and buying advice from our experts.\"}]},{\"URL\":\"pumps\\\/sump-pumps-on-sale.html\",\"displayText\":\"Specials\",\"sectionLinks\":{\"columns\":\"6\",\"linkItems\":[{\"URL\":null,\"imageURL\":null,\"displayText\":\"\"}]},\"subCategories\":[]}],\"USP\":[{\"URL\":\"stories\\\/482-How-To-Get-Free-Shipping-On-Sump-Pumps.html\",\"className\":\"icon-nav-usp-shipping\",\"displayText\":\"Free Shipping\"},{\"URL\":\"stories\\\/357-Top-Sump-Pumps-Worth-Bragging-About.html\",\"className\":\"icon-nav-usp-knowledge\",\"displayText\":\"Expert Knowledge\"},{\"URL\":\"stories\\\/1270-How-to-Finance-Your-Sump-Pump-Purchase.html\",\"className\":\"icon-nav-usp-financing\",\"displayText\":\"Financing\"}]}","siteLinkJSON":"{\"Resources\":{\"How to Library\":{\"href\":\"how-to-library.php\",\"title\":\"Sump Pumps Direct How-To Library\"},\"Product Reviews\":{\"href\":\"reviews.php\",\"title\":\"Customer Reviews on Sump Pumps Direct Products\"},\"Recommendations\":{\"href\":\"stories\\\/357-Top-Sump-Pumps-Worth-Bragging-About.html\",\"title\":\"Product Recommendations\"},\"Weekly Specials\":{\"href\":\"pumps\\\/sump-pumps-on-sale.html\",\"title\":\"Weekly Sump Pumps Direct Specials\"},\"Manuals\":{\"href\":\"stories\\\/396-How-to-Access-Old-Sump-Pump-Manuals.html\",\"title\":\"Manual Lookup\"},\"Service Centers\":{\"href\":\"stories\\\/416-How-to-Find-a-Service-Center-For-Your-Sump-Pump.html\",\"title\":\"Service Centers\"},\"Technical Support\":{\"href\":\"stories\\\/428-How-to-Find-Tech-Support-For-Your-Sump-Pump.html\",\"title\":\"Technical Support\"}},\"Account\":{\"My Account\":{\"href\":\"account.php\",\"title\":\"Login to My Account\"},\"Email Preferences\":{\"href\":\"https:\\\/\\\/www.powerequipmentdirect.com\\\/newsletter_removal.php\",\"title\":\"Email Preferences\"}},\"Customer Service\":{\"Help Center\":{\"href\":\"contact_us.php\",\"title\":\"Help Center\"},\"Return Policy\":{\"href\":\"returns.php\",\"title\":\"Return Policy\"},\"Shipping Policy\":{\"href\":\"stories\\\/518-How-to-Easily-Unload-a-Sump-Pump.html\",\"title\":\"Shipping Policy\"},\"Track Order\":{\"href\":\"ordertracking.php\",\"title\":\"Order Tracking\"},\"Accessibility\":{\"href\":\"stories\\\/1778-Our-Commitment-to-Accessibility.html\",\"title\":\"Accessibility\"}},\"About Us\":{\"Our Story\":{\"href\":\"https:\\\/\\\/www.powerequipmentdirect.com\\\/stories\\\/1982-How-We-Make-Buying-Technical-Products-Simple.html\",\"title\":\"Sump Pumps Direct's Story\"},\"Careers\":{\"href\":\"https:\\\/\\\/www.powerequipmentdirect.com\\\/stories\\\/1924-Job-Openings.html\",\"title\":\"Careers @ Power Equipment Direct\"},\"Newsroom\":{\"href\":\"newsreleases.php\",\"title\":\"Sump Pumps Direct News Center\"}},\"Contact Us\":{\"phone\":\"888-455-4682\",\"hours\":{\"0\":\"M-Th: 8-5 CST\",\"1\":\"Fri: 9-5 CST\",\"2\":\"Sat: Closed\",\"3\":\"Sun: Closed\"}}}","storeLinkJSON":"{\"Air Compressors Direct\":{\"href\":\"https:\\\/\\\/www.aircompressorsdirect.com\\\/\",\"title\":\"Air Compressors Direct\"},\"Chain Saws Direct\":{\"href\":\"https:\\\/\\\/www.chainsawsdirect.com\\\/\",\"title\":\"Chain Saws Direct\"},\"Chippers Direct\":{\"href\":\"https:\\\/\\\/www.chippersdirect.com\\\/\",\"title\":\"Chippers Direct\"},\"eComfort\":{\"href\":\"https:\\\/\\\/www.ecomfort.com\\\/\",\"title\":\"eComfort\"},\"Electric Generators Direct\":{\"href\":\"https:\\\/\\\/www.electricgeneratorsdirect.com\\\/\",\"title\":\"Electric Generators Direct\"},\"Leaf Blowers Direct\":{\"href\":\"https:\\\/\\\/www.leafblowersdirect.com\\\/\",\"title\":\"Leaf Blowers Direct\"},\"Log Splitters Direct\":{\"href\":\"https:\\\/\\\/www.logsplittersdirect.com\\\/\",\"title\":\"Log Splitters Direct\"},\"Mowers Direct\":{\"href\":\"https:\\\/\\\/www.mowersdirect.com\\\/\",\"title\":\"Mowers Direct\"},\"Power Equipment Direct\":{\"href\":\"https:\\\/\\\/www.powerequipmentdirect.com\\\/\",\"title\":\"Power Equipment Direct\"},\"Pressure Washers Direct\":{\"href\":\"https:\\\/\\\/www.pressurewashersdirect.com\\\/\",\"title\":\"Pressure Washers Direct\"},\"Snow Blowers Direct\":{\"href\":\"https:\\\/\\\/www.snowblowersdirect.com\\\/\",\"title\":\"Snow Blowers Direct\"},\"Sump Pumps Direct\":{\"href\":\"https:\\\/\\\/www.sumppumpsdirect.com\\\/\",\"title\":\"Sump Pumps Direct\"},\"Water Pumps Direct\":{\"href\":\"https:\\\/\\\/www.waterpumpsdirect.com\\\/\",\"title\":\"Water Pumps Direct\"}}","socialLinkJSON":"{\"Facebook\":{\"href\":\"https:\\\/\\\/www.facebook.com\\\/SumpPumpsDirect\",\"icon\":\"icon-facebook\",\"title\":\"Facebook\"},\"Twitter\":{\"href\":\"http:\\\/\\\/twitter.com\\\/sumppumpsdirect\",\"icon\":\"icon-twitter\",\"title\":\"Twitter\"},\"Pinterest\":{\"href\":\"http:\\\/\\\/pinterest.com\\\/sumppumpsdirect\\\/\",\"icon\":\"icon-pinterest\",\"title\":\"Pinterest\"},\"YouTube\":{\"href\":\"http:\\\/\\\/www.youtube.com\\\/SumpPumpsDirect\",\"icon\":\"icon-youtube\",\"title\":\"YouTube\"},\"Instagram\":{\"href\":\"https:\\\/\\\/www.instagram.com\\\/powerequipmentdirect\\\/\",\"icon\":\"icon-instagram\",\"title\":\"Instagram\"},\"LinkedIn\":{\"href\":\"https:\\\/\\\/www.linkedin.com\\\/company\\\/power-equipment-direct\\\/\",\"icon\":\"icon-linkedin\",\"title\":\"LinkedIn\"}}","miscLinkJSON":"{\"Manufacturer Login\":{\"href\":\"https:\\\/\\\/www.powerequipmentdirect.com\\\/partnerships\\\/login.php\",\"title\":\"Manufacturer Login\"},\"Terms of Use\":{\"href\":\"terms-of-use.php\",\"title\":\"Terms of Use\"},\"Privacy Policy\":{\"href\":\"privacy.php\",\"title\":\"Privacy Policy\"},\"CA Privacy Rights\":{\"href\":\"privacy.php#californiaPrivacyRights\",\"title\":\"CA Privacy Rights\"},\"copyright\":\" 2022 Power Equipment Direct. Hi there, I'm planning on using this pump and a Jackel sump basin ( or something like that) to move water from a "lake" in my diveway, about 50' horizontally to a flower bed. This is true in sump and sewage applications. Is there any way for me to tell whether it is a 1/3 or 1/2 hp model? Zoeller pumps are known to last but are also known for some switch problems. Yes, you can, but you need to purchase it direct from Zoeller. That said, I have heard of them lasting 10, 15 and 25+ years in some cases. Two questions: 1) the current set up uses 1 inch PVC discharge pipes - up about 8 feet and then horizontal for another 15 feet until exiting the house. Would this pump be suitable for a 12' x 12' basement? You want to pay very close attention to these requirements as they will insure a longer pump life. The weight of the fluid on the topside of the check valve keeps it closed. Since M53 have a built in air relief hole do I need to drill a hole into my PVC pipe? My pump keeps running, is it the switch or the pump? Thank you for your interest in Sump Pumps Direct. Note, in hurricane Irene my pump was going off every minute. This pump is approx 7 years old, seems to work fine , do I need to consider replacing and with what. You might try to brace and/or pad any area of the discharge pipe that may be coming in direct contact with any walls, ceilings or joists to try to reduce the vibration that is being caused by the sudden reversal of the water flow once that pump switches off and that check valve slams shut. If that is not visible, you can measure the height of the pump. Amps times volts give you watts. My basement is 104' and currently takes in approximately 3" of water when there is a hard rain. What kind of warranty do you have on your pumps? The M53 runs at 9.6 amps and requires 25.9 amps to start. Please note however, that you will also need protection in the event of a power outage. Typically, the pump should give you about 5-7 years of life in a standard sump application. Zoeller Complete Cover Assembly & Switch Kit For M53 Sump Pump, Cast Iron Switch Case, Motor & Pump Housing. Would this pump work, and also be one that can handle the sand that comes in mixed with water? These Zoeller submersible sump pumps have a factory set pumping range and are unable to be adjusted to accommodate a higher water level. I purchased a home with a zoeller sump pump already installed in the basement. Even with this air relief hole in the pump, it's still highly recommended that you drill a "weep" hole in your discharge pipe. I would like to know how many watts a 1/3 or 1/2 hp sump pump has, because i was think of buying a portable generator in case the power goes off. If you must reduce the piping, I don't recommend that you go any smaller than 1-1/4". I'm replacing my Zoeller M72 Model with M53. The Zoeller M53 is and has been a great pump for many years! I'd prefer to bypass the switch altogether but not if the compartment can't be sealed properly. I need to buy a generator, so I'm trying to determine what size. HELP!!
2) what is the recommended location for the new check valve? If this doesn't do the job, you might increase to the 1/2HP M98 Zoeller pump with the same 1-1/2" or 2" discharge. I installed according to directions. All is operating well - Leading up to a question, I think I am getting some water hammer. Do I have to replace the pump? The relief hole in the pump will help prevent any air lock within the pump. Other than that, both pumps are the same. WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov. I have cleaned the pump, well and float. That being said, you can make the call on weather you would like to replace the pump or the. As the water level rises so does the float which, at some point, it will trigger the switch to turn the pump on. Thanks. What locations in Anchorge sells your product. When using the formula of amps X volts = watts, you would need a minimum 1152 running watts and 3108 starting watts to operate your pump. You would really need to know the starting amp rating for your ice box to get an accurate number to size your generator. Jim what is the difference between a m53 and a m57 zoeller pump. Thank you for your interest in Sump Pumps Direct. Air locking on a sump pump happens when there is air between the pump and the check valve of the discharge line. The starting amps for the M53 are 25.9. deep. One option you could look at to overcome this, would be to install the non-automatic version. Jim, how can I prevent water and sand from settling below my beach house? All sump & sewage pumps need to be wired according to national electrical codes and all applicable local codes and ordinances. Thank you. Bottom line, this pump is not moving water out fast enough to keep the water from going under the house and into the pool. I can tell you that most average sized homes in an average water table area can usually get away with a 1/3HP or 1/2HP pump. I don't want it to have to run more often then it does now. There is usually a brass tag mounted on the top side of the pump between the the power cord relief and the float switch arm that will give you the model number and date code in addition to the voltage and amps. As with any question that I get on wiring pumps, I must refer you to the fact that all manufactures do state the following: Jim, I currently have a 1/3HP pedestal pump discharging through a 1-1/4" pipe. Thanks, Jim. I want to replace it and was looking at this pump because my existing one is old and noisy. Was thinking about ordering the following kit, but I am not sure if the basin is the correct one for a sump pump or if we should switch it to something bigger. I think older. I am torn between which Zoeller pump would be best for my application. The problem is often noticed after the initial use when the pit has had time to dry out during a dry spell. I have a Zoeller submersible sump pump don't no the model but it has a 9 foot cord, is it a m53? The pump is about 6 years old, should i replace it or is there something else i can do.
If that should happen, it's usually easier to have it serviced at a local authorized Zoeller service center or replace the pump. What kind of draw (startup and normal operation) should I include in my calculations for sizing the generator. Introducing a submersible pump like the Zoeller model M53, should give you a quieter pump but it may very well cycle more frequently than your current 1/3HP pedestal. All the terminals are corroded so it's been running like this for some time. Thereby cycling only maybe only every two hours. These accessories are required to properly setup/install this product. This float has limited movement up and down and side to side, giving it less freedom of movement and less of a chance to get stuck as a tethered float would. Is there a difference between the m53-d mighty mate and the m53. I would like to buy a generator to run that sump pump plus my icebox which takes 6.5 amps/115 volts. I installed the Zoeller M53 with the recommended 1 1/2" Zoeller check valve. IF you have more water than sand, that M53 will handle it. I would suggest increasing the discharge piping from 1-1/4" to 1-1/2" or even 2". Should I buy the 507 or 510? *We currently CANNOT ship this product to Canada or any destination outside of the United States, Zoeller M53 - 1/3 HP Cast Iron Submersible Sump Pump w/ Vertical Float Switch. Could you please tell me what I would need to purchase. It really depends on how you plan on getting the water into the sump basin. Get expert advice and be the first to hear about new products and special promotions. How To Pick The Perfect Pedestal Sump Pump. All Rights Reserved\"}","checkoutMiscLinkJSON":"{\"Privacy Policy\":{\"href\":\"privacy.php\",\"title\":\"Privacy Policy\"},\"Terms of Use\":{\"href\":\"terms-of-use.php\",\"title\":\"Terms of Use\"},\"copyright\":\" 2022 Power Equipment Direct. Your submission has been sent successfully. All Rights Reserved\"}","expertJSON":{"imageURL":"https:\/\/www.powerequipmentdirect.com\/images\/experts\/expert-main-10.png","href":"\/sump-pump-product-expert.php","title":"Contact Jim @ Sump Pumps Direct","expertName":"Jim","expertTitle":"Sump Pump Expert"},"bbbJSON":{"imageURL":"https:\/\/www.powerequipmentdirect.com\/images\/badge-bbb.png","imageAlt":"Better Business Bureau\u00ae","href":"http:\/\/www.bbb.org\/chicago\/business-reviews\/industrial-equipment-and-supplies\/power-equipment-direct-in-bolingbrook-il-57001088","title":"Sump Pumps Direct - A+ Rating - Better Business Bureau\u00ae"},"zipCode":null,"phoneNumber":"888-455-4682","loginToken":"bc937ff5da63b36ffbaeaf02c81b7fd5d7d9f37afcaec14869a97f2b9e909a98","iterable":"e4b27e68b9c84fbb940829a0a9ee29d7","newNav":true}. What am I expected to put between the pump body and the bottom clamp of this check valve? Please review all product specs prior to purchase. i want 2sump pumps 1 higher tha other. Regarding the noise concern, there should not be any difference as long as the pump is installed properly. My concern is that it will be going off even more often if I change to a submersible style pump because it sits lower in the pit. i have 1 zollerm53 if it stops iam done. I mounted the check valve about 5' above the base of the pump, about 2 1/2' above the check valve the pipe makes a 90 degree turn. the pump is not turning off. At this point, you could attach the check valve and then complete your discharge configuration. The "D" series was manufactured between 7/92 and current. I have a Zoeller M53 in a basement sump 24 in. The 1/3HP model is just over 10 inches tall and the 1/2HP model is just over 12 inches tall. The water is only on one side of the basement and never comes up on the other. This is completely normal. There is no info on tag that is attached the plug wire. Is any maintenance required on the M53 pump? You can reach them at (800) 928-7867. the pump rests on the bottom and the float activates Approx. When in doubt, you should contact a licensed electrician in your area. Product Video Disclaimer: "PED is not responsible for any variances from the product in this video and the item you purchase. None, whatsoever. IF that M53 had difficulty with demand at any time however, then I would suggest increasing to the 1/2HP model M98. The switch is the most common reason for failure and can be replaced, though it is a bit involved on the "M" Series models. Unlike Born, raised, and built in the U.S.A., Goulds Water Technology is an American m You'll hardly think about your sump pump until it's too late. Unfortunately, I would not have the answer to that question. If we get heavy rain in a short amount of time, then a heavy flow of water flows directly underneath our house and directly into the pool.
- Blue Dolphin Mablethorpe Site Fees
- Bracelet Designs With Beads
- Bitcoin Ira Vs Itrustcapital
- Hp Laserjet Pro 400 Toner Replacement
- 3 Inch Rubber Coupling Home Depot
- Precision Stepper Motor
- Men's Handmade Leather Sandals
- Cabinet With Lock Ikea
- Terracotta Vases Bulk
- Flojet Macerator Pump Wiring
- Natural Stone Bead Bracelets Wholesale
- King Size Farmhouse Headboard
- International Snack Wholesale Distributors Near Warsaw