Are you sure you want to delete your template? 3722021-13, 3722021-0T7GDY, PF-40-2N22M, PF-50-2N22C, RB818, B236, TT506, 5KCP49ZN9315X, MGT-60-5137, R63MWENB-4728, SpaDepot on Facebook (opens in a new tab), SpaDepot on Instagram (opens in a new tab), SpaDepot on Pinterest (opens in a new tab), SpaDepot Hot Tub Care Blog (opens in a new tab), Pump Suction Reducer Union - 2.5"FBT x 2"SS, Silencer Anti-Vibration Spa Pump Motor Base. Terms, How To Install Spa Pump Waterway - Executive and other 48 Frame Spa pumps. timer intermatic Drain thoroughly and clean out any debris. Before removing the power cable from your old pump, refer to the wiring diagram in the motor connection box lid and record the wire colour going to the high and/or low speed termminals. Thanks for your response. waterway continuity inyopools Wire the common and high speed terminal connections, while leaving the low speed terminal blank. FAILURE TO FOLLOW THESEINSTRUCTIONS EXPLICITLY CAN RESULT IN PERSONAL INJURY.MOTOR WIRING1. Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software. Use Up and Down arrow keys to navigate search results. Loosen the four through-bolts from the back of the motor and pull them back enough to disengage. Protect pump and motor from elements bycovering or, if possible, store in a dry, well ventilate room.MODEL AMP VOLTAGE HMAXPF-10-1N22X 5.0 230 13.4PF-20-1N22X 8.7 230 16.2BROWNLOW SPEED(* BLK)W2 U2 V2PF-20-2N22X 9.3 / 1.8 230 16.2 / 5.0PF-25-2N22X 10.3 / 1.8 230 16.9 / 5.7PF-30-1N22X 12.6 230 19.0BLACKHIGH SPEED(* RED)U1 V1 W1BLUECOMMON(* WHT)GREENGROUNDENSURE WIRING CIRCUIT AGREES WITH DIAGRAM AND LEADS ARE SECURELY TIGHT. Pump: Waterways 56 frame EMG Motor, 2 speed. 0000048229 00000 n I will order again, i am sure. Once the wires have been relaesed you can now remove them from the box through the cable gland. Thanks Spacare, way to go. Use waterway tailpiece assemblies forbest connection. Purchased pump, it came as said, installed very easy. Be the first to review this product! These guys are GREAT, "Worked perfectly. 56-frame executive euro pump safety instructions - Waterway Plastics. H\j0y Executive 56 Frame Waterway Pump 4.0 HP 230 volts 2 speed 2.5" x 2" 3721621-13. There is an adequate amount of water in the system.2.

%%EOF They tend to operate a bit cooler than 48 frame units, which can mean longer service life. This was a direct fit. @[PD0"|Eq_~. Z7Dg8&u&IU$Bj4 It can only be returned for warranty issues if installed. -cuL k8Fvp-0ZoioYV 1c[^`[~{;!Y!] The pump you order needs to say Waterway or it is not the genuine article. 0000047733 00000 n

Be sure to look at the motor voltage, not the voltage supplied to the spa to determine the correct pump voltage. The wiring colour is set/determined by the manufacturer of the Spa,NOTthe motor manufacturer. Pumpshould be protected from excessive moisture.The inlet and outlet have waterway male union threads. pump threads), Wet End Discharge Orientation: Top (can easily be rotated), Waterway Cross Reference: 3722021-13, 3722021-0T7GDY, PF-40-2N22M, PF-50-2N22C, Motor Cross Reference: RB818, B236, TT506, 5KCP49ZN9315X, MGT-60-5137, R63MWENB-4728. Speed: 2-speed: 3450 RPM high/1725 RPM low, Intake: 2.5 plumbing (3.625 O.D. I am in desperate need of some wiring help. | Sitemap. To avoid choosing the incorrect pump, use the Amperage rating listed on the old pump's label to find the correct replacement instead of the horsepower. Some pipe dopes not approved for use with plastic will cause stress cracking ofplastic parts. Waterway Executive Spa Pump Wiring Diagram, Executive wet end designed specifically for 56-frame motors, Two double shielded ball bearings with moisture resistant grease for quieter operation and longer life, Two speed motors have four sets of insulated windings for increased efficiency, 56-frame motor for added strength, cooler operating temperature, and longer motor life, Larger 2" intake for improved flow performance and reduced noise, Large 6-1/2" diameter wet end for higher head pressure, Split capacitor, (start and run) for less energy consumption, Thermally protected to extend life expectancy of motor, Highly versatile wet end can be rotated 90 degrees either way, Dimensions (H x W x L): 9.08" x 8.05" x 10.375". For disconnection from the supply, a circuit breaker having a contact separation of at least3mm in all poles must be incorporated in the fixed wiring according to the wiring rules.Cord and plug provided with pump is intended to be used with mating spa pack connector.9. Outside Dimension Of The Front Face Plate Measures 7-1/2". Your old existing pump will have been connected to your Spa pack via a plug-in connector that is moulded to your pump power lead.

Hello all you brilliant people. FOR SAFETY CLASS 1 EQUIPMENT: It is mandatory to connect the pump to the protectiveconductor (grounding connector) of earth-grounded main power supply.FOR EQUIPOTENTIAL BONDING: It is also possible in addition to use the externalterminal on the body to realize an equipotential bonding with other earthed metallic parts.6. I take safety very seriously and would not attempt this if I do not think I can make this a safe project. If supply cord isdamaged, replace only with original replacement equipment available from authorized dealer.The pump is to be supplied through a residual current device (RCD) with a rated residualoperating current not exceeding 30mA.Potential risk of fire, electrical shock, or injury to persons if misused.DO NOT install within an outer enclosure or beneath the skirt of the spa unless so marked.WARNING: To reduce the risk of injury, do not permit children to use this product unless theyare closely supervised at all times.CAUTION: This pump is for use with permanently installed pools and may also be used withhot tubs and spas if so marked. Be sure to look at the motor voltage, not the voltage supplied to the spa to determine the correct pump voltage. All valves are open to allow water circulation.3. Waterway uses various motor manufacturers, so capacitor location may be external or internal. In this video The Spa Guy shows you How To Read and understand a Hot Tub Pump Motor Wiring Schematic and wire your Hot Tub Pump motor.. hb```f``YAX, Z> aV13DO+SpbrY V'$2:@ADet *aUXQAq-^0_083p13D]]O=m :|1000^g5cj*I Q4#q : 0000051861 00000 n New installations often require a plumbing inspection. Then rotate the wet end to the desired position realign and re-tighten the bolts. The larger 56 frame motors are a little more expensive and somewhat stronger. H\0?'BdvG d69EHjffsv We Only Ship in the USA on this site.. For Our Parts Site to Ship Outside of the USA Click Here.. Pump must be installed below water surface. Rep was great directing me to correct product! 0000011973 00000 n Century Capacitor Start / Induction Run No Base, Century Capacitor Start / Induction Run Rigid Base, Century Capacitor Start/Run Resilient Base, All Swimming Pool Equipment, Pumps & Toys, Armstrong, B & G Hot Water Circulator Pumps, All Armstrong, B & G Hot Water Circulator Pumps, Condenser Motor Capacitor Wiring Instructions, Canadian Ground Shipments - Click Here for Details - Ships from Michigan, 3721621-1D Waterway | 4HP 230V 2-Speed Waterway Spa Pump Side Discharge | 56 Frame Executive, 3722021-1D Waterway | 5HP 230V 2-Speed Waterway Spa Pump Side Discharge | 56 Frame Executive, 3721221-13 Waterway | 3HP 230V 2-Speed Waterway Spa Pump Side Discharge 2 1/2" inlet | 56 Frame Executive, 3721621-13 Waterway | 4HP 230V 2-Speed Waterway Spa Pump Side Discharge 2 1/2" inlet | 56 Frame Executive, 3722021-0V Waterway | 5HP Viper Spa Pump Side Discharge |2-Speed, 56 Frame Executive, 131602.00 Leeson | 5hp 1740 RPM 184TC Frame (Farm Duty) 230 Volts, 3421821-1A Waterway | 4.5HP 230V 2-Speed Waterway Spa Pump Side Discharge | 48 Frame Executive, 310-1830 Waterway | 5 hp Executive 2.5" x 2" Side Discharge Wet End 48/56 Frame, 8B64-SF Pulley | 6.75" OD Eight Groove "A/B" Pulley / Sheave (bushing not included), 3720821-1D Waterway | 2HP 230V 2-Speed Waterway Spa Pump Side Discharge | 56 Frame Executive, Armstrong B & G Hot Water Circulator Pumps. We won't add your friend's name to our email list unless they choose to sign up. The diagram on the pump doesn't make sense to me either since it shows line 2 going to nothing? "Quick response through chat for which pump I needed.". The connector will beeither a grey 'JJ' plug or an AMP type plug. Waterway Executive 56-Frame Side DischargeSpa PumpModel3722021-13, Inlet Thread Diameter - 3 5/8"Outlet Thread Diameter - 3", Model: 3722021-13, 3722021-1385U, 3722021-1385, Waterway pump fit Spa Pumps, Hot Tubs, Bath Tubs, Jacuzzi Tubs, Whirlpool Tubs. Make sure that the moter is switched off and isolated. 0000001512 00000 n All Rights Reserved. We will contact you as soon as this product is available. Choosing a pump based on Horsepower (HP) can be misleading. The pump head can be rotated by simply loosening the motor thru bolts and turning the pump head, allowing the discharge to point to the left at 11 o'clock position. It is a brand new OEM Waterway pump with a 1 Year warranty. With a 7mm spanner, undo the nuts from each terminal post one at a time. If your pump is supplied with a cable and has bare wire ends, Hydrospares can supply a connection that will prevent the need to open the motor electrical box. 0000015792 00000 n DO NOT ground to a gas supply line.7. Waterway pump repair, Waterway pump manual. Performing this action will revert the following features to their default settings: Performing this action will permanently remove your draft from Yumpu. Use only Teflon tape or other sealing compounds approved for usewith plastic. Note: The Inlet and outlet are two different sizes on this pump. Was told on how to get the replacement I needed since model numbers are the same for 2 different options". The connection diagram for the new pump is located on the motor name plate. f/0,vl:C#U&"v*y=9^T*"^~9^UuGtrzj7cvd0=|}M:0p9_cqjz " vZTlJ}g gz|=)]|g1(Tl{abTK /u M Heater Info on Spa Heater Elements, Spa Heaters, Hot Tub Heating Elements. 22 40 0000095669 00000 n pump threads), Discharge: 2 plumbing (3 O.D. 2.0 Pump thread measures approx. 0000051443 00000 n Shutoff valves should be installed on both the inlet and outlet of the pump for future maintenance.Installation area should be clear of any direct water and have adequate floor drainage. In most cases you need to match the existing form factor to get the components to match up. Pump plumbing sizes are nominal and not actual outside diameter (O.D.) 5.5" diameter, or 56 frame, which are approx. Before you remove the power cord from your old pump, look at the old motor wiring label and make a note of what color goes to high, and to low.

Copyright 20XXSpa Pumps And More. 0000038696 00000 n A pressure regulator should be used when preformingthis test and should not exceed 40 PSI during the pressure test. 650mkay;dLN1zV_Ii/6K}Xf nTY*S~JB^O=%e?2xyob\dKsS{WW 2wG NAn&3QdY,Y,[PB;jM?~P Thank you! The pump does not come with a power cord. Thanks!! Spa main pumps will have a size of either 48 frame, which are approx. Thanks. Run a wire from one load side of the toggle switch to 2 on the motor. 61 0 obj <>stream Our 2-speed pumps can easily be configured for 1-speed. 0000003387 00000 n Product Notes: 220 - 240V. Since motor manufacturers do not label frame size consistently, you should determine a motor's frame size by measuring the spacing between the through-bolts on the back of the motor. I have no experience in selecting toggle switches for this application, but general rule of thumb, ensure it's rated for the voltage and amperage you are running. I agree with the other comment, please stop and call an electrician. If the pump willnot start or prime, see the troubleshooting section in the manual.MAINTENANCE INSTRUCTIONSKeep the motor clean. HAND TIGHT UNIONS ONLY!Do not use pipe dope. Part no. The filter and pump are underpressure. 0000008135 00000 n Good quality pump and motor, ordered late Wednesday and received Friday fed x ground low shipping cost and low price on pump and motor. Note: Because of their lower cost and compact size, most spa pumps in service are 48 frame. Hooray! Do not overtighten. You will find a range of problem-solving worksheets ready for you to print & keep.

If you care about yourself or any other friends or family who will be using this hot tub it will be a very small price to pay for the knowledge that everything is hooked up safe and proper. 0000000016 00000 n This was not noticeable until I ran the pump at high speed then it leaked significantly. This item is not available for delivery to Alaska, Hawaii, or Canada.

The physical size of the pump motor is referred to as frame. If you want to eliminate the toggle switch, run one hot line to line 1, run line 2 to both 2 and 3or4 on the motor. of the threaded intake or discharge. 0000005300 00000 n New pumps ship without a power cord. %VLd*2(?R-bnmRr)U YEXoa}m8=rIg@h7NhR"vjE. When not using the switch, I don't believe you connect to both 2 and 3/4, you just pick one for the speed you need. These unions allow the pump to be removed for service without disturbing theplumbing.

Sitemap 7

waterway executive 56 wiring diagram