If your underground pipework contains mechanical joints, you must also be able to visually inspect each joint at any time. For fixed tanks, mobile bowsers, IBCs and other single containers, the secondary containment must have capacity to hold 110% of the capacity of the container. 3) Any valve, filter, sight gauge, vent pipe or other equipment ancillary to the container (other than a fill pipe or draw off pipe or, if the oil has a flashpoint of less than 32C, a pump) must be situated within the secondary containment system. Though not mentioned in the commercial regulations specifically, it is also worth giving some thought to fire safety and anti-theft measures when considering your installation location, i.e. The best thing you can do is contact the Environment Agency to discuss whether the container you have is strong enough and in good enough condition to still be used. 0000013881 00000 n waste oil and motor oil, Liquid bitumen-based products e.g. They must not be galvanised and must be painted to reduce corrosion. must be adequately protected from physical damage; iii. There are separate requirements for storing agricultural fuel oil on a farm in England or Wales for agricultural purposes, for example as fuel for a tractor or to power a grain dryer. Any other oil drained from vehicle engines. Trade counter tools and accessories to provide everything you need to complete your project. This document covers the essential technical aspects of oil storage for both business and home applications. This could be something that cuts off the flow of oil to the tank when its full, or an alarm or fixed tank probe that sends a signal to alert the person filling the tank when the tank is full. Fixed tanks that meet the design standard are any made to British Standard 5410, or: OFTEC is a trade association for the oil heating and cooking industry. [h3V3\. We believe excellent service before and after your order is paramount to our continued success. In a remote fill, the tank may not be visible from the fill point. 0000002997 00000 n These rules apply to service boats. Must not have any pipe, valve, or other opening in the base or walls of the bund that allow it to be drained. Aromatic hydrocarbons (e.g.

Call us today on 0330 123 1444 to order one of our fuel tanks or dispensing products, or simply for some advice. You must only fill the tank up to 85% to leave room for expansion and to avoid any spillages. You must make sure the valve and filter are accessible for routine maintenance and emergencies. If the fill point of your fixed tank has a screw fitting or fixed coupling, it must be used when youre having your tank filled. If you have multiple fixed tanks, mobile bowsers, or IBCs, the secondary containment around them must have a capacity that is equal to of the combined total of all containers or 110% of the largest container, whichever measurement is greater. We've noticed you have got JavaScript disabled. 0000003756 00000 n Ducting and access products for utility services and infrastructure. We would strongly recommend that you contact a local OFTEC registered technician or one registered with the Building Regulations Competent Person Scheme for further advice on installing and maintaining oil storage tanks. 0000003401 00000 n

Call us on 0330 123 1444 and we will be able to offer advice from a team of experts. fuel drained from a diesel car that's been accidentally filled with petrol). Again, you must contact your local PEA who can issue you one for up to 3 years, but this is non-transferable. In this article, we will take a closer look at the regulations for storing oil on commercial premises. e.g. Important Note: If you plan to build a bund from masonry or concrete, be aware that it will probably need a rendering or special coating on the internal surfaces to make the base and walls impermeable. Cutting fluids (e.g. These classifications may seem a bit pedantic, especially since the regulations for each are broadly similar. If you have a new or replacement fuel container installed at your home, such as for your cooker or central heating, you must adhere to building regulations. 0000093074 00000 n A drip tray is designed to catch any spillages to prevent oil from entering the environment. 0000002913 00000 n This tap or valve must not be able to be fixed open unless it also has an automatic cut off mechanism. Or you must make sure that any impact will not damage the container, for example by placing barriers or bollards around the tank. Oil Storage Tanks - what type of tank do you need? Must have a storage capacity that is at least 110% that of the oil container it is to surround. installed in the right place to avoid damage while also allowing for safe filling and maintenance access. It will take only 2 minutes to fill in. But what do you do if you have a container that doesn't meet these standards? For bunds of either variety you must make sure: Bunds constructed from masonry and concrete are likely to need a rendering or coating on the internal surfaces of the base and walls to make them impermeable. Any property used for business purposes (including marinas) and public sector buildings, such as schools, hospitals, and leisure centres, are all classed as commercial premises under this regulation. Fixed tanks must be bunded you cannot use a drip tray for them. 0000081447 00000 n According to the advice on the government's website, an oil storage container can be any of the following: Certain types of generators (ones with a connected oil supply tank that has a capacity of 201 litres or more) can also be classed as oil storage containers if they are: Again, it may seem obvious that all of the above would be classified as oil containers covered by the commercial regulations. 0000004526 00000 n Vegetable oils (including any oil derived from a plant, such as sunflower oil or plant-based oils used in aromatherapy). Secondary containment for commercial oil containers usually comes in the form of either a drip tray placed beneath it or a sealed outer case around it - also known as a bund. Any underground pipework should be suitably protected from vibration damage, accidental digging damage, and corrosion (if metal pipes are used). 0000003493 00000 n in daily use with a supply tank that has a capacity which isn't used up in one day. This is because "waste oil" is a catch-all term that needs to be broken down into the various types to better explain. 7) Where oil from the tank is delivered through a flexible pipe which is permanently attached to the container. Secondary containment is required to prevent oil escaping from the tank or ancillary equipment in the event of a leakage or spill. It can harm plants and marine life, damage rivers, groundwater and soil and destroy natural habitats and drinking water supplies. 0000019808 00000 n We supply 205-litre red diesel barrels that are constructed from welded mild steel and a wide array of tanks that vary in shape, size and capacity. must be positioned/protected in such a way as to minimise the risk of damage and or leaks. Ideally, you want to locate it away from driveways, tanker turning circles, forklift truck routes, and any other areas where there is an increased risk of it being damaged by impact. Make sure sight gauges, delivery pipes, and pumps all have the appropriate valves to keep the oil secure when not in use. if fitted with a leakage detection device which is used continuously to monitor for leaks, the detection device must be maintained in working order and tested at appropriate intervals to ensure that it works properly; and, v. if not fitted with such a device, must be tested for leaks before it is first used and further tests for leaks must be performed, in the case of pipes which have mechanical joints, at least once in every 5 years and, in other cases, at least once in every 10 years; and. Keep the delivery pipe in a locked cabinet to prevent misuse. The screw fitting and fixed coupling must not become eroded. For example if your container has a capacity of 2,500 litres, your secondary containment must have capacity for 2,750 litres. If your tank has underground pipework, you must make sure the pipework is protected from physical damage, for example by: If the pipework is made of a material that can be corroded such as steel or copper, you must also make sure its protected against corrosion, for example by: You must check any underground pipes attached to your fixed tank for leaks. It must be: You can also gauge using a drip rod that is constructed from non-sparking alloys that are unearthed. If you are in the market for high-quality polyethylene oil tanks, we stock a great range of bunded tanks over in our Oil Storage Tanks section that we'd recommend taking a look at. A remote fill is when you fill your container at a fill point thats outside the secondary containment (the bund or drip tray designed to capture leaks from the container). Hydrocarbon products (those that are solid unless they are heated, e.g. We have a wide range of fuel services on offer, including environmental services, designed to help you get the most out of your fuels, such as: To find out how Crown Oil can benefit your business, call us on 0330 123 1444. 0000006140 00000 n 0000006195 00000 n That being said, however, you also need your container to be as close as possible to wherever the oil is needed in order to avoid overly long pipelines that pose a greater failure risk. This seems relatively straightforward, but there are two points that can be a bit ambiguous if not further explained; what is classed as commercial premises and to what type of oil containers does this refer?

0000003969 00000 n don't install an oil container where sparks fly, open flames burn, or temperatures get really high, and try to keep them hidden from the prying eyes of unscrupulous passers-by. Note: The information that follows is for above ground oil storage containers only. Oil Firing Technical Association (OFTEC) standard OST T100 - for plastic containers. Underground pipes should also have a permanent leak detection device installed, otherwise it will need to be tested every 5 (if it contains mechanical joints) to 10 (if it doesn't contain mechanical joints) years. You are looking out for any signs of corrosion and wear and tear, and also any sudden reductions in the level of your fuel, which might indicate a leaking heating oil tank. Linear channel drainage for the collection and distribution of surface water. Marina service boats are not considered premises for onward distribution, if they sell oil directly to boat owners. 3) Where oil is delivered through a flexible pipe which is permanently attached to the unit. If you fill your container through a remote fill pipe, you must use a drip tray to catch any oil spillages that may occur during the delivery. Contact the Environment Agency if your container does not meet one of these standards or have a UN marking, and you want to discuss whether its strong enough and has enough structural integrity. 0000002641 00000 n (a) the pipe must be fitted with a manually operated pump or with a valve at the delivery end which closes automatically when not in use; (b) the pump or valve must be provided with a lock and locked shut when not in use; (c) the pipe must be fitted with a lockable valve at the end where it leaves the container and must be locked shut when not in use. Our sister company, Crown Oil Environmental has a team of fully-trained inspectors to get in the tanks where most cannot, enabling our oil tank inspections to be extremely cost-effective. This is only valid if you use the tray to hold a single drum. All fuel tanks and ancillaries must be positioned in an oil tight secondary containment system, such as a bund or drip tray. Commercial oil supply pipes tend to be constructed from steel to provide protection from damage and vandalism. Any leaks or faults in your tank can be not only costly but potentially dangerous too, so its imperative that it is well maintained, regularly cleaned and handled safely. It will have to come down to good old fashioned common sense and/or advice from a professional installer. However, they may still fall under other storage regulations or safety measures, so it is worth doing further research if you plan to store any of them. trichloroethylene). (c) if made of materials which are liable to corrosion, must be adequately protected against corrosion. Basically, if the oil you are storing isn't being used for domestic purposes (i.e. If a low-risk location isn't available or practical, one solution to this is to place barriers or bollards around the storage container to give it some protection. 2) Any sight gauge must be properly supported and fitted with a valve which must be closed automatically when not in use. 0000003812 00000 n Any pipework above the ground must be properly supported, for example by a bracket connected to the nearest wall. Products for the collection, storage or treatment of foul & waste water. However, knowing when your tank will fall under commercial regulations can be a little less so. On the contrary, the pipe must be kept inside the bund, where the pipe leaves the oil tank. Identifying problems early on will reduce the likelihood of hefty costs. You should only use the rod in the tank that it was specifically designed for to guarantee accurate readings. Fixed tanks must be bunded. These rules do not apply to them, but they do apply to oil depots at airports owned by airlines. 0000003077 00000 n 0000081322 00000 n If you have any questions regarding the storage of your fuel tank, please call us on 0330 123 1444 for help and advice from our team of experts. Important Note: if you do use a remote fill (i.e. This is imperative to prevent an oil spillage. The law requires different containers, depending on how much fuel you are storing: You can store over 30 litres but less 275 litres of petrol, but you must inform your local PEA via writing, with your name, address and storage location. News stories, speeches, letters and notices, Reports, analysis and official statistics, Data, Freedom of Information releases and corporate reports. You do not need to follow them if you store any of the following types of waste oil but you should check if you need an environmental permit: You do not need to follow these rules if your storage containers are: If you store oil in a building, you may need to meet additional fire safety measures under the Building Regulations contact your local council to discuss whether this is the case for your store. That brings us neatly onto point number two. On top of that, you also need to think about how the tank will be filled. 0000001588 00000 n You must ensure your tank is installed by someone who is registered with a Competent Person scheme as they can self-certify that their own work adheres to building regulations. If you have any questions, or want to speak to our team of experts about your fuel and oil storage needs, call us on 0330 123 1444.

During a remote fill, the tank might not be visible from the fill point. When your tank is being installed, the company must ensure the work complies with Building Regulations 2010. 0000003258 00000 n Liquid bitumen-based products (e.g. benzene and toluene). If the drip tray can hold more than one drum, it must be able to hold one quarter of the combined capacity of the drums it can hold. at a refinery or premises for onward distribution of oil (i.e. If you use a company that is not fully qualified, it will be your responsibility if any pollution is caused as a result of poor fuel or oil storage.

0000002663 00000 n The containers must be designed solely for the purpose of oil storage and must be fitted with a screw cap or closure to avoid leakage of liquid or vapour. Use brackets to support any above ground fill pipes, draw-off pipes, and overflow pipes to the nearest wall. They are ideal for plant equipment and machinery that need regularly refilling. Biodegradable oils (typically lubricating or hydraulic oils). If your fixed tank has a pump, the pump must: If your fixed tank has any permanently attached vent pipes, taps or valves that oil can leave the tank through, all pipes, taps and valves must: We consider that an isolating valve or filter on a fixed draw-off pipe, fitted outside an integrally bunded tank, is ancillary to the downstream equipment, not to the container. You must install secondary containment around your container to catch any oil that leaks. While the primary intention of all oil tank regulations is to protect the oil from the environment and the environment from the oil, the ways in which this is achieved differ enough across the three types of use to warrant further discussion.

All of our barrels and tanks are perfect for storing all fuels and oils and can even be tailor-made to suit your exact requirements. 0000004237 00000 n If the building is on a farm in England or Wales, you must meet the requirements for storing agricultural fuel oil. Hb``b`pe`c`Led@ A; CH,nW0`A3i6QKvB. 2) The container must be situated within a secondary containment system which satisfies the following requirements. 0000008741 00000 n All of our storage facilities come hand in hand with our wide range of ancillary products that are designed to help increase safe handling and storage.

If you use a bund, it must hold 110% of the capacity of the container. If you do not have a bund, check your secondary containment has the required capacity, depending on what kind of container its holding. We also use cookies set by other sites to help us deliver content from their services. If you do not follow the relevant requirements for storing oil, you can be fined or prosecuted. (a) the pipe must be fitted with a tap or valve at the delivery end which closes automatically when not in use; (b) the tap or valve must not be capable of being fixed in the open position unless the pipe is fitted with an automatic shut off device; (c) the pipe must be enclosed in a secure cabinet which is locked shut when not in use and is equipped with a drip tray or the pipe must, i. have a lockable valve where it leaves the container which is locked shut when not in use; and. First off, one point that isn't specifically mentioned in the requirements above is that fixed tanks MUST be bunded. Dont include personal or financial information like your National Insurance number or credit card details. If your fuel tank is near a river or water source, the company is required to fit a secondary containment, such as a bund to prevent any oil spillages. It is also important to use a trusted and professional company to carry out an industrial tank inspection at least once a year. Fuel tanks require a gauge to help the delivery driver when they are refuelling the tank to prevent overfilling and spillages. 0000010722 00000 n Mixtures of diesel and petrol which can no longer be used as vehicle fuel (e.g. Now we just need to take a look at what the actual rules are for storing commercial use oil. An outer skin designed to give the tank extra strength can only be classed as a bund if there is enough space between it and the inner tank to hold 110% of the inner tank's storage capacity. fuelling tractors or powering grain dryers), it's going to be classed as commercial use. 0000004172 00000 n Storing diesel or any other fuel in the workplace or at home presents a potential risk to both yourself and the environment: when not handled correctly, fuels are a dangerous and highly flammable substance that can cause big problems. 400, 500 & 630mm OD Sewer Pipe & Fittings, Building Regulations Competent Person Scheme, Control of Pollution (Oil Storage) (England) Regulations 2001, Control of Pollution (Silage, Slurry and Agricultural Fuel Oil), 1991. Three different regulations in England regulate the storage of oil. home heating) or agricultural purposes (i.e. Our team of experts are always on hand to help with all of your civils and drainage needs. 4) The tank must be fitted with an automatic overfill prevention device if the filling operation is controlled from a place where it is not reasonably practicable to observe the tank and any vent pipe. Section 'Oil types': added content about 'grease' and clarified - when you do not need to follow rules 'if impractical to provide secondary containment' and 'hydrocarbon products'. How to store oil, design standards for tanks and containers, where to locate and how to protect them, and capacity of bunds and drip trays. 0000003123 00000 n If the vent pipe of a fixed tank, and the tank itself, cannot be seen from where the tank is filled you must fit an automatic overfill prevention device to the tank. Find out more below. Before you go running off to install your new oil container, however, there are a few extra rules you'll need to follow if you plan to use fixed tanks or mobile bowsers to store your oil. Products for above ground foul and surface water drainage. And that's it for the general rules for storing oil on a commercial property. You cannot use a drip tray as secondary containment for an oil storage tank. Bunded fuel tanks are the most reliable fuel facility to store fuel safely and securely. This can entail an apparatus to cut off the oil when the tank is full or an alarm or fixed tank probe to send an alert when its full. If you have or are interested in an underground oil storage tank, they are covered by the Defra Groundwater Protection Code instead. A gauge is a traditional method used to measure the contents of a bottom outlet oil tank. You must follow the rules on storing oil if youve got an oil storage container with a capacity of 201 litres or more at a: You must also follow these rules if youve got an oil storage container with a capacity of 3,501 litres or more at a home, including barges and houseboats. Oil is one of the most common reports of pollution, contributing to over 15% of pollution incidents each year. an access point to a fill pipe that is outside the protection provided by the container's secondary containment feature), you MUST ensure there is a drip tray installed to catch any oil spilled during the delivery. JDP uses cookies to make this site simpler. Products and accessories for farming and agriculture and keeping happy & healthy livestock. 1) Any fixed tank used for storing oil shall satisfy the following requirements. 0000004069 00000 n 'stand-by' generators kept for emergency use. We use some essential cookies to make this website work. Domestic oil supply pipes are usually constructed from plastic-coated soft copper tubing to enable them to be easily manipulated. It is a legal requirement that the pipework is supported so it cannot become loose. You must check that debris has not become trapped within. But you must follow the rules for businesses in this guide if you store oil on a farm for non-agricultural business purposes, for example to fuel lorries or trucks.

It must remain locked when not in use, with a valve or tap at the input end that secures automatically. 0000005690 00000 n Given that all oil tanks should always be installed by a registered professional technician (preferably OFTEC approved), we'd probably get them to advise you on the best location anyway. Other containers can be bunded or use drip trays. The Environment Agency can also serve an anti-pollution works notice to make you bring your oil store up to legal standards. It must be: Pipes are a potential source of an oil leakage, so they must have a shut-off valve that has been tested to BS EN ISO 10497 and therefore fire safe. A valve is an imperative safety feature of an oil tank installation as it cuts off the oil supply in the event of a fire. These vary in Wales, Scotland and Northern Ireland. JDP offers a range of other products and services in this category: Products for collecting, distributing and managing surface water. The drip tray will ensure the fuel is contained within as it is attached to the bottom of the tank. If you are installing or managing an oil storage tank on commercial premises in Scotland or Northern Ireland, please make sure that you research the relevant regulations for your area and follow them over any conflicting advice given in this article. Whether you choose a plastic or steel tank will depend on your operations. 10 metres away from any inland freshwaters or coastal waters. Check benefits and financial support you can get, Department for Environment, Food & Rural Affairs, Fixed tanks with underground pipework: additional requirements, requirements for storing agricultural fuel oil, check if you need an environmental permit, advice on how to construct bunds that meet these requirements, Storing silage, slurry and agricultural fuel oil, Prevent groundwater pollution from underground fuel storage tanks, RP29: Self-supporting covers for slurry and anaerobic digestate stores, Natural England: Building partnerships for Natures recovery, public sector building like a school, hospital or leisure centre, mobile bowsers containers designed to store and dispense oil that can be moved between locations but not under their own power, vegetable oils, including any oil derived from a plant such as sunflower oil or plant-based oils used in aromatherapy, synthetic oils normally lubricating oils like motor oil, biodegradable oils usually lubricating or hydraulic oils, liquid bitumen-based products, for example waterproofing or damp proofing products, or coatings for a road surface, cutting fluids, for example lubricants designed specifically for metalworking processes, that are made from or contain oil as oil-water emulsions, insulating oils, used as electrical insulator and coolant, hydrocarbon products that are solid unless they are heated, such as bitumen, solvents that are not oil based such as trichloroethylene, aromatic hydrocarbons like benzene and toluene, mixtures of diesel and petrol which can no longer be used as vehicle fuel, for example fuel drained from a diesel car thats been accidentally filled with petrol, creating a mixture, any other oil drained from vehicle engines, at a premises for onward distribution of oil, rather than a premises which sells oil directly to end users, stored in a building a permanent or temporary structure with walls and a roof that would capture oil leaking from the container, generators in daily use with a tank that supplies the generator where all of the oil from the tank is not used in 1 day, stand-by generators, which are generators kept for emergency use, a bund an outer case which holds the container, double-skinned or twin-walled tanks, where the tank is surrounded by a second outer skin for extra strength, one quarter of the combined capacity of all the containers, 110% of the capacity of the largest container, manufactured as part of a tank system tanks that are pre-bunded by the manufacturer in this way are known as integrally bunded tanks, the bund is impermeable to oil and water oil and water cannot pass through, the base or walls of the bund do not have a pipe, valve or opening that allows the bund to be drained, any fill pipe or draw-off pipe that passes through the bund base or wall is sealed to stop oil getting out of the bund, the bund contains every part of the container and its associated equipment (such as valves) unless the oil being stored has a flash point of less than 32 (such as ethanol), in which case filters, sight gauges, valves and other equipment can sit outside the bund, have a bracket or brackets along the length of the sight gauge tube that fix the tube to the tank so the sight gauge tube cannot be knocked over, be fitted with a valve that closes automatically when the gauge is not in use, there must be a lockable valve at the point where the pipe leaves the oil tank, this valve must be locked shut when the pipe is not in use, have a valve in its feed line that prevents the tank contents emptying if theres damage to the pump or feed line, be positioned to minimise the risk of damage by impact, for example away from driveways, tanker turning circles, and fork lift truck routes, or protected by bollards or barriers, be secured to prevent theft of the oil, for example by locking the pump shut when its not in use, or cutting the supply of electricity to the pump so it cannot function when not in use, or enclosing the pump in a lockable cage, be arranged so any oil coming out of them will go vertically down into the bund, have a lock and be locked shut when not in use this only applies to taps and valves, not vent pipes, preventing vibration damage from lorries driving over ground that has pipework installed underneath, placing a layer of specialist tape in the ground above the underground pipework, to alert anyone digging that pipework is laid beneath, laying the pipework in a trench filled with a material that will drain water, like compacted sand, detecting changes in the pressure in the pipe, every 5 years if it contains mechanical joints, every 10 years if it does not contain mechanical joints, the lock must be locked shut when the tap or valve is not in use, to prevent oil flowing, any flexible delivery pipe permanently attached to the bowser the lock should be at the point the pipe leaves the bowser, any manually operated pump, like a hand pump, the valve on the delivery end of the flexible pipe attached to any automatic pump, for example an electric pump the valve must close automatically when the pump is not in use, like the nozzle on a pump at a petrol station.